E3609-70 ISO 10993-5 & -10 compliant EPDM O-rings
Parker’s 70 durometer EPDM compound E3609-70 has successfully passed ISO 10993-5 and -10 requirements. This material is also compliant to USP Class VI and USP <87>.
ISO 10993-5 evaluates materials for their potential to kill cell cultures. ISO 10993-10 tests materials for sensitivity and biological response. These standards are accepted in both the United States and the European Union for rubber materials used in surgical instruments, drug delivery devices, pharmaceutical and biopharmaceutical manufacturing, and other medical device applications.
Product Highlights:
- Excellent resistance to repeated steam, gamma, ozone, and ethylene oxide sterilization
- Compliant with ISO 10993- 10 and USP Class VI biocompatibility standards
- Compliant with ISO 10993-5 and USP <87> cytotoxicity standards
Parker’s 70 durometer EPDM compound E3609-70 has successfully passed ISO 10993-5 and -10 requirements. This material is also compliant to USP Class VI and USP <87>.
ISO 10993-5 evaluates materials for their potential to kill cell cultures. ISO 10993-10 tests materials for sensitivity and biological response. These standards are accepted in both the United States and the European Union for rubber materials used in surgical instruments, drug delivery devices, pharmaceutical and biopharmaceutical manufacturing, and other medical device applications.
- Excellent resistance to repeated steam, gamma, ozone, and ethylene oxide sterilization
- Compliant with ISO 10993- 10 and USP Class VI biocompatibility standards
- Compliant with ISO 10993-5 and USP <87> cytotoxicity standards
- Low compression set,
- Temperature range -65° to +250°F
- Compatible with all water-soluble chemistries
This warranty comprises the sole and entire warranty pertaining to items provided hereunder. seller makes no other warranty, guarantee, or representation of any kind whatsoever. All other warranties, including but not limited to, merchant ability and fitness for purpose, whether expressed, implied, or arising by operation of law, trade usage, or course of dealing are hereby disclaimed. Notwithstanding the foregoing, there are no warranties whatsoever on items built or acquired wholly or partially, to buyer’s designs or specifications. Limitation of remedy: Seller’s Liability arising from or in any way connected with the items sold or this contract shall be limited exclusively to repair or replacement of the items sold or refund of the purchase price paid by buyer, at seller’s sole option. In no event shall seller be liable for any incidental, consequential or special damages of any kind or nature whatsoever, including but not limited to lost profits arising from or in any way connected with this agreement or items sold hereunder, whether alleged to arise from breach of contract, expressed or implied warranty, or in tort, including without limitation, negligence, failure to warn or strict liability.
- Details
-
Parker’s 70 durometer EPDM compound E3609-70 has successfully passed ISO 10993-5 and -10 requirements. This material is also compliant to USP Class VI and USP <87>.
ISO 10993-5 evaluates materials for their potential to kill cell cultures. ISO 10993-10 tests materials for sensitivity and biological response. These standards are accepted in both the United States and the European Union for rubber materials used in surgical instruments, drug delivery devices, pharmaceutical and biopharmaceutical manufacturing, and other medical device applications.
- Excellent resistance to repeated steam, gamma, ozone, and ethylene oxide sterilization
- Compliant with ISO 10993- 10 and USP Class VI biocompatibility standards
- Compliant with ISO 10993-5 and USP <87> cytotoxicity standards
- Low compression set,
- Temperature range -65° to +250°F
- Compatible with all water-soluble chemistries
- Specs
- Resources
- Warranty
-
This warranty comprises the sole and entire warranty pertaining to items provided hereunder. seller makes no other warranty, guarantee, or representation of any kind whatsoever. All other warranties, including but not limited to, merchant ability and fitness for purpose, whether expressed, implied, or arising by operation of law, trade usage, or course of dealing are hereby disclaimed. Notwithstanding the foregoing, there are no warranties whatsoever on items built or acquired wholly or partially, to buyer’s designs or specifications. Limitation of remedy: Seller’s Liability arising from or in any way connected with the items sold or this contract shall be limited exclusively to repair or replacement of the items sold or refund of the purchase price paid by buyer, at seller’s sole option. In no event shall seller be liable for any incidental, consequential or special damages of any kind or nature whatsoever, including but not limited to lost profits arising from or in any way connected with this agreement or items sold hereunder, whether alleged to arise from breach of contract, expressed or implied warranty, or in tort, including without limitation, negligence, failure to warn or strict liability.